Ice Oxygen K-edge NEXAFS Spectroscopy Data List

This table lists raw NEXAFS spectroscopy data files used to study the impact of water partial pressure on ice X-ray absorption spectra. Each row represents a measurement file containing parameters such as X-ray photon energy (eV), sample and ice temperatures (°C), and cell pressure (mbar). The data covers measurements taken between August and November 2020 for ice and gas-phase samples.

This table serves as a metadata index for raw spectroscopy files, allowing researchers to identify specific experimental conditions (temperature, pressure) associated with each file. It does not contain the actual spectral intensity values or the raw X-ray absorption curves themselves.

16 rows · 22 columns · published by EnviDat · licence: Open use, source must be named, ask before commercial use

Source file: https://www.envidat.ch/dataset/316d5fcf-76f0-4921-807f-2ea1d3e9f7bc/resource/4523fcaa-78b… · the dataset

Columns

ColumnTypeDescription
Raw File NameTEXTThe name of the raw data file in .h5 format.
Min X-ray Photon EnergyFLOATThe smallest X-ray photon energy measured, in electronvolts (eV).
Max X-ray Photon EnergyFLOATThe largest X-ray photon energy measured, in electronvolts (eV).
Analyzer Pass EnergyINTEGERThe pass energy of the electron analyzer, in electronvolts (eV).
Analyzer Dwell TimeINTEGERThe dwell time of the electron analyzer, in milliseconds (ms).
Spectral RegionBOOK_NAMEThe spectral region being measured, specifically the O K-edge.
Acquisition ModeSTRINGThe mode of acquisition, such as 'Fixed' energy snapshot mode.
Min Kinetic Energy WindowFLOATThe lower bound of the kinetic energy window for detection, in eV.
Max Kinetic Energy WindowFLOATThe upper bound of the kinetic energy window for detection, in eV.
Kinetic Energy StepNULLThe kinetic energy step size, not defined for fixed energy mode.
Lens ModeSTRINGThe lens mode setting used, e.g., T_HiPPHAXPES.
Region IterationsINTEGERThe number of sweeps performed for the region.
Sequence IterationsINTEGERThe number of sweeps performed for the sequence.
Sample Holder TemperatureFLOATThe temperature monitored at the sample holder, in degrees Celsius (°C).
Cell Total PressureFLOATThe total pressure within the measurement cell, in millibars (mbar).
Calculated Ice TemperatureFLOATThe calculated temperature of the ice sample based on vapour pressure, in °C.
Sample X PositionFLOATThe X-coordinate position of the sample, in millimeters (mm).
Sample Y PositionFLOATThe Y-coordinate position of the sample, in millimeters (mm).
Sample Z PositionFLOATThe Z-coordinate position of the sample, in millimeters (mm).
Sealing TemperatureFLOATThe temperature of the sealing mechanism.
Last Modified DateDATETIMEThe timestamp of when the data file was last modified.
Sample TypeSTRINGThe type of sample measured, such as 'O_K-edge ice' or 'gas-phase'.

Questions it answers

Query it in SQL · API · Use it from an AI agent (MCP) · More tables

Cleaned and typed by Data Cleaner: open this file in Data Cleaner or clean your own file.